Inspection and Test Plan for Method Statement: Geothermal Production Wellhead Equipment and Piping Installation
AI-assisted inspection and test plan connected to a method statement, with PDF and Excel export.
More than a static template
Unlike a downloadable Word or PDF template, this ITP is an AI-assisted editable starting point directly connected to its method statement. Every inspection activity, hold point, and acceptance criterion is structured and ready to adapt to your project.
- AI-assisted customization — Tailor inspection activities and acceptance criteria to your specific project scope.
- Linked method statement — This ITP is connected to the corresponding method statement describing the work sequence.
- Multiple export formats — Download as a formatted PDF or editable Excel spreadsheet.
- Editable starting point, not a final document — Review and verify all content against your project specifications and standards before use.
What you can customize
When you save this ITP to your account, every inspection row becomes editable. You can add, remove, or modify:
- Inspection activity — Description of what is being inspected.
- Inspection type — Hold point (H), Witness point (W), Review (R), or Monitor (M).
- Responsibility — Contractor, subcontractor, engineer, or client.
- Frequency — How often the inspection occurs.
- Acceptance criteria — Referenced standard or specification requirement.
- Records — Forms, test reports, or checklists required as evidence.
Why this ITP is used
To ensure critical construction activities meet code, specification, and manufacturer requirements with documented verification.
Who uses this inspection and test plan
Contractor QA/QC, Site Engineers, NDE personnel, and Client/Engineer representatives.
When this ITP is prepared and submitted
From material receipt through final walkdown and turnover to operations.
Who receives or approves this ITP
Client/Engineer for review and approval.
Inspection scope
Covers materials verification, fit-up, welding parameters, NDE (VT/RT/PT/MT), PWHT, pressure testing, bolting, insulation/cladding, and final documentation.
Typical hold, witness, and review points
Master valve installation (H), RT interpretation (H), hydrotest (H), fit-up/welding parameters (W), insulation checks (W).
Typical inspection records
MTCs, PMI logs, fit-up and weld maps, NDE and PWHT reports, torque sheets, hydrotest packs, insulation reports, and MDR sign-off.
Important approval note
This ITP is an AI-assisted editable starting point, not a pre-approved document. Before use on any project, all inspection activities, hold points, and acceptance criteria must be reviewed and approved by the relevant parties (superintendent, principal contractor, or client representative) in accordance with your contract and project quality plan.
Always verify acceptance criteria against your applicable drawings, specifications, and regulatory requirements. Hold points must be confirmed with the relevant authority before work proceeds past that point.
Inspection and test plan
| Activity | Inspection / Test | Acceptance Criteria | Responsibility | Record |
|---|---|---|---|---|
| Material receipt and PMI | Check MTCs, visual, PMI per plan | Materials match spec/grade/size; PMI within alloy range; documentation complete | QC Inspector / Client (W) | Receiving report, PMI log, MTCs |
| Foundation/anchor verification | Survey and level checks | Elevation and bolt positions within tolerance | Site Engineer / Client (W) | Survey report |
| Master valve installation | Face condition, gasket type, orientation | API 6A compatibility; correct gasket; no damage | QC Inspector / Client (H) | Inspection checklist |
| Bolt torque/tension verification | Torque/tension values and pattern | Within specified bolt stress; uniform gap | QC / Client (W) | Torque record |
| Piping fit-up inspection | Root gap, hi–lo, bevel angles | Per WPS and ASME B31.3 tolerances | Welding Inspector / Client (W) | Fit-up report, weld map |
| Welding parameters and preheat | Preheat/interpass, parameters | Within WPS limits | Welding Inspector | Weld log |
| Intermediate VT/PT/MT | VT 100%, PT/MT as specified | No relevant indications beyond code | QC / Client (W) | NDE reports |
| PWHT (if applicable) | Thermocouple placement; temp/time charts | Within WPS/PQR limits | Welding Engineer / Client (W) | PWHT charts |
| Radiographic testing (RT) | RT per ASME V or ISO 17636 | ASME B31.3 acceptance criteria | NDE Level II/III / Client (H) | RT reports/images |
| Pressure test | Hydrotest per B31.3 | No leaks; hold and pressure criteria met | Test Engineer / Client (H) | Hydrotest pack |
| Insulation and cladding inspection | Thickness, fit, overlap, weatherproofing | Per spec; thickness +5/−0 mm; overlaps per method | QC / Client (W) | Insulation/Cladding reports |
| Final walkdown and documentation | Punch closure, tags, nameplates | All items closed; MDR complete | QA/QC Manager / Client (W) | Punch list, MDR sign-off |
This table is a read-only public reference. Download the PDF or Excel version, or customize this ITP to edit it for your project.
Frequently asked questions
Related method statement
This Inspection and Test Plan is associated with the Method Statement: Geothermal Production Wellhead Equipment and Piping Installation method statement, which describes the step-by-step construction sequence, resources, materials, equipment, safety controls, and environmental controls for this activity.
View the Method Statement: Geothermal Production Wellhead Equipment and Piping Installation method statement →Continue with related inspection, method statement, article, and checklist resources.














